Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
1.
Prenat Diagn ; 39(13): 1204-1212, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31600419

RESUMO

OBJECTIVE: To determine whether complex gastroschisis (ie, intestinal atresia, perforation, necrosis, or volvulus) can prenatally be distinguished from simple gastroschisis by fetal stomach volume and stomach-bladder distance, using three-dimensional (3D) ultrasound. METHODS: This multicenter prospective cohort study was conducted in the Netherlands between 2010 and 2015. Of seven university medical centers, we included the four centers that performed longitudinal 3D ultrasound measurements at a regular basis. We calculated stomach volumes (n = 223) using Sonography-based Automated Volume Count. The shortest stomach-bladder distance (n = 241) was determined using multiplanar visualization of the volume datasets. We used linear mixed modelling to evaluate the effect of gestational age and type of gastroschisis (simple or complex) on fetal stomach volume and stomach-bladder distance. RESULTS: We included 79 affected fetuses. Sixty-six (84%) had been assessed with 3D ultrasound at least once; 64 of these 66 were liveborn, nine (14%) had complex gastroschisis. With advancing gestational age, stomach volume significantly increased, and stomach-bladder distance decreased (both P < .001). The developmental changes did not differ significantly between fetuses with simple and complex gastroschisis, neither for fetal stomach volume (P = .85), nor for stomach bladder distance (P = .78). CONCLUSION: Fetal stomach volume and stomach-bladder distance, measured during pregnancy using 3D ultrasonography, do not predict complex gastroschisis.


Assuntos
Gastrosquise/diagnóstico por imagem , Adulto , Feminino , Humanos , Imageamento Tridimensional , Estudos Longitudinais , Gravidez , Estudos Prospectivos , Estômago/diagnóstico por imagem , Estômago/embriologia , Ultrassonografia Pré-Natal , Adulto Jovem
2.
Osteoarthritis Cartilage ; 27(3): 513-525, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30513362

RESUMO

OBJECTIVE: We earlier identified that the histone methyltransferase Disruptor of telomeric silencing 1-like (DOT1L) is as a master protector of cartilage health via limiting excessive activation of the Wnt pathway. However, cartilage-specific homozygous Dot1l knockout mice exhibited a severe growth phenotype and perinatal death, which hampered their use in induced or ageing models of osteoarthritis (OA). The aim of this study was to generate and examine haploinsufficient and inducible conditional Dot1l-deficient mouse models to evaluate the importance of DOT1L during post-traumatic or ageing-associated OA onset and progression. METHOD: We used cartilage-specific heterozygous and postnatal tamoxifen-inducible Dot1l knockout mice and performed destabilization of the medial meniscus (DMM) and ageing as OA models. Mice were examined histologically using X-rays and micro-computed tomography (µCT), and cartilage damage and osteophyte formation were assessed based on OARSI guidelines. Immunohistochemistry of DOT1L, H3K79me2, TCF1 and COLX was performed. RESULTS: Both Dot1l-deficient strains exhibit a phenotype characterized by joint remodeling with extensive osteophyte formation and ectopic ossification upon ageing, indicating accelerated development of spontaneous osteoarthritis. In the DMM-induced OA mouse model, absence of Dot1l resulted in increased cartilage damage. Wnt signalling hyper-activation and ectopic chondrocyte hypertrophy were observed in the articular cartilage of both Dot1l-deficient mice. CONCLUSIONS: This study demonstrated the functional relevance of DOT1L in vivo during the development of OA using genetically modified mice. Thus, maintaining or enhancing DOT1L activity during ageing or after trauma might prevent OA onset and progression.


Assuntos
Histona-Lisina N-Metiltransferase/deficiência , Articulações/lesões , Osteoartrite/etiologia , Animais , Articulações/diagnóstico por imagem , Articulações/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Osteoartrite/diagnóstico por imagem , Radiografia , Microtomografia por Raio-X
3.
Talanta ; 170: 343-349, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28501179

RESUMO

A chromatographic method based on the use of a fused-core column and luminescence detection is described for the determination of six penicillin antibiotics used in veterinary practice, namely amoxicillin, ampicillin, penicillin G, oxacillin, cloxacillin and nafcillin. The use of this column provides the separation of these antibiotics with retention times lower than 4.5min. The tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)32+] - Ce(IV) system has been used as post-column derivatization reagent, obtaining a luminescence signal (λem 610nm) proportional to the analyte concentration when the system is excited at 450nm. The dynamic ranges of the calibration graphs are 100-10,000ngmL-1 for all the antibiotics assayed and the limits of detection are in the range of 44-51ngmL-1. The precision, established at two concentration levels of each analyte and expressed as the percentage of the relative standard deviation is in the range of 6.9-9.8%. The method has been satisfactorily applied to the analysis of water and pharmaceutical samples, with recoveries ranging from 88.6% to 108.5%.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Água Potável/análise , Penicilinas/análise , Drogas Veterinárias/análise , Poluentes Químicos da Água/análise , Cromatografia Líquida de Alta Pressão/economia , Cromatografia Líquida de Alta Pressão/instrumentação , Desenho de Equipamento , Limite de Detecção , Medições Luminescentes/economia , Medições Luminescentes/instrumentação , Medições Luminescentes/métodos , Preparações Farmacêuticas/química , Fatores de Tempo
4.
Early Hum Dev ; 103: 209-218, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27825040

RESUMO

OBJECTIVE: To determine outcome of children born with isolated gastroschisis (no extra-gastrointestinal congenital abnormalities). STUDY DESIGN: International cohort study and meta-analysis. PRIMARY OUTCOME: time to full enteral feeding (TFEF); secondary outcomes: Duration of mechanical ventilation, length of stay (LOS), mortality and differences in outcome between simple and complex gastroschisis (complex; born with bowel atresia, volvulus, perforation or necrosis). To compare the cohort study results with literature three databases were searched. Studies were eligible for inclusion if cases were born in developed countries with isolated gastroschisis after 1990, number of cases >20 and TFEF was reported. RESULTS: The cohort study included 204 liveborn cases of isolated gastroschisis. The TFEF, median duration of ventilation and LOS was, 26days (range 6-515), 2days (range 0-90) and 33days (range 11-515), respectively. Overall mortality was 10.8%. TFEF and LOS were significantly longer (P<0.0001) and mortality was fourfold higher in the complex group. Seventeen studies, amongst the current study, were included for further meta-analysis comprising a total of 1652 patients. Mean TFEF was 35.3±4.4days, length of ventilation was 5.5±2.0days, LOS was 46.4±5.2days and mortality risk was 0.06 [0.04-0.07 95%CI]. Outcome of simple and complex gastroschisis was described in five studies. TFEF, ventilation time, LOS were significant longer and mortality rate was 3.64 [1.95-6.83 95%CI] times higher in complex cases. CONCLUSIONS: These results give a good indication of the expected TFEF, ventilation time and LOS and mortality risk in children born with isolated gastroschisis, although ranges remain wide. This study shows the importance of dividing gastroschisis into simple and complex for the prediction of outcome.


Assuntos
Gastrosquise/epidemiologia , Gastrosquise/diagnóstico , Gastrosquise/terapia , Humanos , Lactente , Mortalidade Infantil , Recém-Nascido , Tempo de Internação/estatística & dados numéricos , Nutrição Parenteral/estatística & dados numéricos , Respiração Artificial/estatística & dados numéricos
6.
J Chromatogr A ; 1425: 73-80, 2015 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-26627586

RESUMO

A new magnetic dispersive solid-phase extraction approach based on Eu- and Tb-coated magnetic nanocomposites, combined with ultra-high performance liquid chromatography with fluorometric detection, is reported for the extraction and simultaneous determination of veterinary antibiotics. The method is aimed at monitoring of potential residues of three tetracyclines, namely oxytetracycline, tetracycline, chlortetracycline and three acidic quinolones, such as oxolinic acid, nalidixic acid and flumequine, chosen as model analytes, in animal muscle samples. The nanocomposites were obtained by synthesizing magnetic nanoparticles by a co-precipitation method and their coating with terbium and europium ions. The limits of detection obtained using standard solutions were: 1.0, 1.5, 3.8, 0.25, 0.7 and 1.2ngmL(-1), which corresponds to 3.3, 5.0, 12.7, 0.8, 2.3 and 4.0µgkg(-1) for oxytetracycline, tetracycline, chlortetracycline, oxolinic acid, nalidixic acid and flumequine, respectively, in meat samples. The precision values, obtained in the presence of the sample matrix, were in the ranges 0.12-2.0% and 2.6-15.4% for retention times and areas, respectively. The selectivity of the method was checked by assaying different veterinary drugs, finding that most of them did not interfere at the same concentration levels as that of analytes. A recovery study was performed in the presence of chicken and pork muscle samples, which provided values in the range of 61.5-102.6%.


Assuntos
Antibacterianos/análise , Resíduos de Drogas/análise , Európio/química , Carne/análise , Nanocompostos , Quinolonas/análise , Térbio/química , Tetraciclinas/análise , Animais , Galinhas , Cromatografia Líquida de Alta Pressão/métodos , Extração em Fase Sólida/métodos , Suínos , Drogas Veterinárias/análise
7.
J Chromatogr A ; 1405: 126-32, 2015 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-26077970

RESUMO

The usefulness of terbium oxide nanoparticles (Tb4O7NPs) as post-column derivatizing reagent for the liquid chromatographic determination of residues of quinolone antibiotics in milk samples has been studied. Seven quinolones of veterinary use have been chosen as model analytes to develop this method. The derivatization step is based on the formation of luminescent chelates of quinolones with Tb4O7NPs, which are monitored at λex=340nm and λem=545nm. Another relevant feature of the method is that the use of a 10-cm column and a ternary mixture of methanol, acetonitrile and acetic acid as mobile phase in gradient elution mode allow the chromatographic separation of the quinolones in about 13min, whereas previously described chromatographic methods require about 20min. The dynamic ranges of the calibration graphs and limits of detection are, respectively: 65-900ngmL(-1) and 35ngmL(-1) for marbofloxacin, 7.2-900ngmL(-1) and 2.5ngmL(-1) for ciprofloxacin, 6-900ngmL(-1) and 2ngmL(-1) for danofloxacin, 50-900ngmL(-1) and 20ngmL(-1) for enrofloxacin, 35-900ngmL(-1) and 12ngmL(-1) for sarafloxacin, 5-900ngmL(-1) and 2ngmL(-1) for oxolinic acid, and 7-900ngmL(-1) and 2.5ngmL(-1) for flumequine. The precision, established at two concentration levels of each analyte and expressed as the percentage of the relative standard deviation is in the range of 1.9-8.1% using standards, and of 3.4-10.7% in the presence of milk samples. The method has been satisfactorily applied to the analysis of skimmed, semi-skimmed and whole milk samples, with recoveries ranging from 89.0 to 106.5%.


Assuntos
Antibacterianos/análise , Complexos de Coordenação/análise , Leite/química , Quinolonas/análise , Térbio/química , Animais , Cromatografia Líquida/métodos , Fluoroquinolonas/análise , Nanopartículas
8.
Artigo em Inglês | MEDLINE | ID: mdl-25660719

RESUMO

A new method based on ultra high performance liquid chromatography (UPLC) with photometric and fluorometric detection for the determination of acetylsalicylic acid and its main metabolites, namely gentisic, salicylic and salicyluric acids, in bovine urine samples is reported. Photometric detection was used for acetylsalicylic acid determination, whereas the native fluorescence of the metabolites was monitored using fluorometric detection. The separation was performed under isocratic conditions, using acetonitrile-phosphate solution (3.5mM, pH 3.5) (26:74, v/v) as the mobile phase. The retention times of the four compounds were lower than 2min, which are shorter than those achieved using conventional HPLC. Under the optimum separation conditions, the dynamic ranges and detection limits (ngmL(-1)) were: 0.2-2500, 0.09 for gentisic acid; 0.2-2500, 0.08 for salicylic acid and 2.5-15,000, 1.1 for salicyluric acid, using fluorescence detection, and 10-25,000, 2.2 for acetylsalicylic acid, using UV detection. Intra-day and inter-day precision data were assessed at two levels of concentration of each analyte using both detection systems. The selectivity of the method was checked by assaying different drugs of veterinary use showing that most of them did not interfere with the determination of the analytes. The method has been applied to the analysis of bovine urine samples, which only required a simple clean up step of the samples prior to injection in the UPLC system. A recovery study was performed, which provided values in the range of 80-100%. This fact proves the practical usefulness of this method as an ultrafast analytical tool for the therapeutic control of acetylsalicylic acid administration in bovine animals intended for food production.


Assuntos
Aspirina/metabolismo , Aspirina/urina , Cromatografia Líquida de Alta Pressão/métodos , Animais , Bovinos , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes
9.
Am J Obstet Gynecol ; 212(3): 348.e1-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25447962

RESUMO

OBJECTIVE: To evaluate the management of imminent preterm delivery with respect to prescription of antenatal corticosteroids (ACS) and referral to a tertiary center. STUDY DESIGN: A retrospective cohort study existing of 1 perinatal center and 9 referring hospitals. All women who received their first dose of ACS in 1 of the 10 hospitals between 24+0 and 32+0 weeks of gestation and/or delivered before 32 weeks of gestation from 2005 until 2010. Patients were identified using the electronic database of hospital pharmacies. Main outcome measures were time interval from administration to delivery for different indications and number of women who were not referred in time to a tertiary center. RESULTS: In total, 1375 women received ACS. Main indications were suspected preterm labor (44.7%), preterm prelabor rupture of membranes (15.9%), maternal indication (12.8%), fetal indication (9.2%) and vaginal blood loss (8.4%). Overall, 467 (34.0%) women delivered ≤7 days after ACS administration; 8.7% of women with vaginal blood loss and 54.5% of women with maternal indication. Among the 931 women who received ACS in the secondary hospitals, 452 (48.5%) women were referred to a tertiary hospital and 89 (6.5%) women delivered in a secondary hospital with a gestational age of less than 32 weeks. CONCLUSION: One-third of all women receiving ACS delivered within 7 days and half of the women who received ACS in a secondary hospital were referred to a tertiary center. There seems to be room for improvement regarding the timing of ACS administration and subsequently referral to a tertiary center.


Assuntos
Betametasona/uso terapêutico , Ruptura Prematura de Membranas Fetais/tratamento farmacológico , Glucocorticoides/uso terapêutico , Doenças do Prematuro/prevenção & controle , Trabalho de Parto Prematuro/tratamento farmacológico , Padrões de Prática Médica/estatística & dados numéricos , Cuidado Pré-Natal/métodos , Adulto , Esquema de Medicação , Feminino , Seguimentos , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Estimativa de Kaplan-Meier , Masculino , Países Baixos , Gravidez , Nascimento Prematuro , Cuidado Pré-Natal/estatística & dados numéricos , Encaminhamento e Consulta/estatística & dados numéricos , Estudos Retrospectivos , Centros de Cuidados de Saúde Secundários , Centros de Atenção Terciária , Fatores de Tempo
10.
Eur J Clin Microbiol Infect Dis ; 33(11): 2005-14, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24916950

RESUMO

The benefits of using urine for the detection of human papillomavirus (HPV) DNA have been evaluated in disease surveillance, epidemiological studies, and screening for cervical cancers in specific subgroups. HPV DNA testing in urine is being considered for important purposes, notably the monitoring of HPV vaccination in adolescent girls and young women who do not wish to have a vaginal examination. The need to optimize and standardize sampling, storage, and processing has been reported.In this paper, we examined the impact of a DNA-conservation buffer, the extraction method, and urine sampling on the detection of HPV DNA and human DNA in urine provided by 44 women with a cytologically normal but HPV DNA-positive cervical sample. Ten women provided first-void and midstream urine samples. DNA analysis was performed using real-time PCR to allow quantification of HPV and human DNA.The results showed that an optimized method for HPV DNA detection in urine should (a) prevent DNA degradation during extraction and storage, (b) recover cell-free HPV DNA in addition to cell-associated DNA, (c) process a sufficient volume of urine, and (d) use a first-void sample.In addition, we found that detectable human DNA in urine may not be a good internal control for sample validity. HPV prevalence data that are based on urine samples collected, stored, and/or processed under suboptimal conditions may underestimate infection rates.


Assuntos
DNA Viral/isolamento & purificação , Papillomaviridae/isolamento & purificação , Infecções por Papillomavirus/diagnóstico , Manejo de Espécimes/métodos , Urina/virologia , Adolescente , Adulto , Feminino , Humanos , Técnicas de Diagnóstico Molecular/métodos , Papillomaviridae/genética , Infecções por Papillomavirus/virologia , Reação em Cadeia da Polimerase em Tempo Real , Adulto Jovem
11.
PLoS One ; 9(6): e90834, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24603723

RESUMO

OBJECTIVE: To evaluate the value of biomarkers to detect severe NEC. SUMMARY BACKGROUND DATA: The time point of surgery in necrotizing enterocolitis (NEC) is critical. Therefore, there is a need for markers that detect severe NEC, because clinical signs of severe NEC often develop late. This study evaluated the value of biomarkers reflecting intestinal cell damage and inflammation to detect severe NEC. METHODS: 29 neonates with NEC were included. Two definitions of moderate versus severe NEC were analyzed: medical NEC (n = 12) versus surgical or fatal NEC (n = 17); and Bell stage II NEC (n = 13) versus stage III NEC (n = 16). Urinary intestinal fatty acid binding protein (I-FABP), serum amyloid A (SAA), C3a and C5a, and fecal calprotectin were measured. C-reactive protein (CRP), white blood cell count (WBC) and platelet count data were measured in blood. RESULTS: In both definitions of moderate versus severe NEC, urinary SAA levels were significantly higher in severe NEC. A cut-off value of 34.4 ng/ml was found in surgical NEC versus medical NEC (sensitivity, 83%; specificity, 83%; LR+, 4.88 (95% CI, 1.37-17.0); LR-, 0.20 (95% CI, 0.07-0.60)) at diagnosis of NEC and at one day prior to surgery in neonates who were operated later on. Combination of urinary SAA and platelet count increased the accuracy, with a sensitivity, 94%; specificity, 83%; LR+, 5.53 (95% CI, 1.57-20.0); and LR-, 0.07 (95% CI, 0.01-0.48). CONCLUSION: Urinary SAA is an accurate marker in differentiating severe NEC from moderate NEC; particularly if combined with serum platelet count.


Assuntos
Enterocolite Necrosante/diagnóstico , Proteína Amiloide A Sérica/urina , Biomarcadores/urina , Complemento C3a/urina , Complemento C5a/urina , Enterocolite Necrosante/cirurgia , Enterocolite Necrosante/urina , Proteínas de Ligação a Ácido Graxo/urina , Fezes/química , Feminino , Humanos , Recém-Nascido , Limite de Detecção , Masculino , Contagem de Plaquetas , Curva ROC , Índice de Gravidade de Doença
12.
Talanta ; 119: 111-5, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24401392

RESUMO

The usefulness of europium oxide nanoparticles (Eu2O3 NPs) as analytical reagent for the direct determination of organic compounds is described for the first time. Tetracycline, which forms a luminescent chelate with europium, has been chosen as a model analyte. Dry reagent chemistry is used in a 96-well format, which considerably speeds up the determination and contributes to its automation. The NPs are immobilized onto polystyrene wells by adding a volume of a Eu2O3 NP dispersion in 2-propanol to each well and drying in an oven until they dry completely. At the moment of analysis, a standard or sample volume (200 µL) in the appropriate medium is added, and the mixture shaken for 15 min at 37°C. The method allows the determination of tetracycline in the range 20-1000 ng mL(-1), with a detection limit of 8 ng mL(-1). The inter-assay and intra-assay precision, which were assayed at two different tetracycline concentrations and expressed as relative standard deviation, were in the ranges of 6.5-8.2% and 9.2-12.7%, respectively. The study of the selectivity of the system showed that the method is adequate for tetracycline determination in agri-food samples, since most of antibiotics assayed did not interfere the determination. Only other tetracycline antibiotics provided luminescent signal when reacting to Eu2O3 NPs. The method has been applied to the determination of tetracycline in calf urine and in honey samples obtaining recovery values in the ranges of 85.0-110.0% and 99.7-116.7%, respectively.


Assuntos
Antibacterianos/análise , Európio/química , Nanopartículas , Tetraciclinas/análise , Ensaios de Triagem em Larga Escala , Mel/análise
13.
BMJ Open ; 4(10): e005652, 2014 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-25763794

RESUMO

OBJECTIVE: To assess the implementation and first results of a term perinatal internal audit by a standardised method. DESIGN: Population-based cohort study. SETTING: All 90 Dutch hospitals with obstetric/paediatric departments linked to community practices of midwives, general practitioners in their attachment areas, organised in perinatal cooperation groups (PCG). POPULATION: The population consisted of 943 registered term perinatal deaths occurring in 2010-2012 with detailed information, including 707 cases with completed audit results. MAIN OUTCOME MEASURES: Participation in the audit, perinatal death classification, identification of substandard factors (SSF), SSF in relation to death, conclusive recommendations for quality improvement in perinatal care and antepartum risk selection at the start of labour. RESULTS: After the introduction of the perinatal audit in 2010, all PCGs participated. They organised 645 audit sessions, with an average of 31 healthcare professionals per session. Of all 1102 term perinatal deaths (2.3/1000) data were registered for 86% (943) and standardised anonymised audit results for 64% (707). In 53% of the cases at least one SSF was identified. Non-compliance to guidelines (35%) and deviation from usual professional care (41%) were the most frequent SSF. There was a (very) probable relation between the SSF and perinatal death for 8% of all cases. This declined over the years: from 10% (n=23) in 2010 to 5% (n=10) in 2012 (p=0.060). Simultaneously term perinatal mortality decreased from 2.3 to 2.0/1000 births (p<0.00001). Possibilities for improvement were identified in the organisation of care (35%), guidelines or usual care (19%) and in documentation (15%). More pregnancies were antepartum selected as high risk, 70% in 2010 and 84% in 2012 (p=0.0001). CONCLUSIONS: The perinatal audit is implemented nationwide in all obstetrical units in the Netherlands in a short time period. It is possible that the audit contributed to the decrease in term perinatal mortality.


Assuntos
Auditoria Médica , Morte Perinatal , Mortalidade Perinatal , Nascimento a Termo , Causas de Morte , Estudos de Coortes , Humanos , Recém-Nascido , Países Baixos/epidemiologia , Morte Perinatal/etiologia , Fatores de Tempo
14.
J Matern Fetal Neonatal Med ; 27(5): 516-9, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23826626

RESUMO

OBJECTIVE: To evaluate the prescribing patterns of the first antenatal corticosteroids (ACS) course in our tertiary referral centre from 2005 until 2010. STUDY DESIGN: We conducted a retrospective cohort study including all women who received ACS between 24(+0) and 34(+0) weeks of gestation. Main outcome measure was the number of women who delivered within 7 d after ACS administration. The time interval from administration to delivery was compared between women with different indications. Furthermore, all women delivering between 24(+0) and 34(+0) weeks of gestation who did not receive ACS were identified. RESULTS: 1008 women received ACS, 15 (1.5%) women were lost to follow up. Main indications were suspected preterm labour, preterm prelabour rupture of membranes, maternal indication, foetal indication and vaginal blood loss (VBL). Overall, 447 (45.4%) women delivered ≤7 d after ACS administration. This percentage was 13.6% in women with VBL and 61.5% in women with maternal indication. During the study period, 1267 women delivered before 34 weeks of gestation, 126 (9.9%) women did not receive ACS. CONCLUSIONS: The time interval from ACS administration to delivery differs per indication. Women with VBL are most often over treated. The timing of the first ACS course should be improved.


Assuntos
Corticosteroides/uso terapêutico , Trabalho de Parto Prematuro/prevenção & controle , Padrões de Prática Médica/estatística & dados numéricos , Adulto , Parto Obstétrico/estatística & dados numéricos , Feminino , Humanos , Recém-Nascido , Trabalho de Parto Prematuro/epidemiologia , Trabalho de Parto Prematuro/etiologia , Gravidez , Resultado da Gravidez/epidemiologia , Estudos Retrospectivos , Fatores de Risco
15.
Food Chem ; 142: 249-54, 2014 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-24001838

RESUMO

Reverse-phase liquid chromatographic methods using a hydrophobic C18 monolithic column and on-line photometric and fluorimetric detection for the determination of the major casein (CN) proteins in milk are presented. The separation of αs1-CN, αs2-CN, ß-CN and κ-CN was achieved in only five minutes. Fluorimetric detection enabled better analytical results than photometric detection. Thus, the dynamic ranges of the calibration graphs and detection limits obtained using fluorimetric detection were (mgmL(-)(1)): αs1-CN (0.74-10.0, 0.22), αs2-CN (0.15-10.0, 0.045), ß-CN (0.68-10.0, 0.20) and κ-CN (0.21-10.0, 0.06). The analytical features of the photometric method, which does not allow the quantification of ß-casein, were (mgmL(-)(1)): αs1-CN (1.5-9.0, 0.45), αs2-CN (1.4-10.0, 0.43) and κ-CN (0.4-9.0, 0.12). Precision data, expressed as relative standard deviation, ranged between 0.6% and 5.3% for the fluorimetric method and between 2.4% and 6.2% for the photometric method. Both methods were applied to the analysis of three different milk samples, obtaining recoveries in the ranges of 86.6-103.2% and 92.0-106.5% using fluorimetric and photometric detection, respectively.


Assuntos
Caseínas/análise , Cromatografia Líquida de Alta Pressão/métodos , Fluorometria/métodos , Leite/química , Fotometria/métodos , Animais , Cromatografia Líquida de Alta Pressão/instrumentação , Fluorometria/instrumentação , Fotometria/instrumentação
16.
Acta Obstet Gynecol Scand ; 92(1): 85-93, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22994792

RESUMO

OBJECTIVE: To assess substandard care factors in the case of delivery-related asphyxia. DESIGN: Prospective cohort study. SETTING: Catchment area of the Neonatal Intensive Care Unit (NICU) of the University Medical Center Utrecht; a region in the middle of the Netherlands covering 13% of the Dutch population. POPULATION: Term infants, without congenital malformations, who died intrapartum or were admitted to the Neonatal Intensive Care Unit due to asphyxia. METHODS: During a two-year period, cases were prospectively collected and audited by an expert panel. MAIN OUTCOME MEASURES: Substandard care factors. RESULTS: 37 735 term infants without congenital malformations were born. There were 19 intrapartum deaths, and 89 NICU admissions of which 12 neonates died. In 63 (58%) cases a substandard care factor was identified that was possibly (n= 47, 43%) or probably (n= 16, 15%) related to perinatal death or NICU admission. In primary care, substandard care factors were mainly the low frequency of examination during labor and delay in referral to secondary care. In secondary care, misinterpretation of cardiotocography and failure to respond adequately to clinical signs of fetal distress were the most common substandard care factors. CONCLUSIONS: Substandard care is present in a substantial number of cases with delivery-related asphyxia resulting in perinatal death or NICU admission. Improving the organization of obstetric care in the Netherlands as well as training of obstetric caregivers might reduce adverse outcomes.


Assuntos
Asfixia Neonatal/etiologia , Parto Obstétrico/efeitos adversos , Qualidade da Assistência à Saúde , Adulto , Asfixia Neonatal/epidemiologia , Cardiotocografia , Feminino , Humanos , Recém-Nascido , Países Baixos/epidemiologia , Gravidez , Resultado da Gravidez/epidemiologia , Estudos Prospectivos , Fatores de Risco
17.
Pediatr Res ; 73(2): 209-13, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23154757

RESUMO

BACKGROUND: Reintroduction of enteral nutrition in neonates with necrotizing enterocolitis (NEC) should take place when the gut is ready for its normal function. Too early a start of oral feeding might lead to disease relapse, whereas prolonged discontinuation of enteral nutrition is associated with impaired gut function and parenteral nutrition-related complications. This study evaluated whether noninvasive urinary measurement of intestinal fatty acid binding protein (I-FABP) at the time of refeeding can predict clinical outcome in neonates with NEC. METHODS: Urinary I-FABP concentrations were measured in 21 infants with NEC just before reintroducing enteral nutrition. Poor outcome was defined as unsuccessful reintroduction of enteral feeding (EF), (re)operation for NEC, or death related to NEC after reintroduction of EF. RESULTS: Median urinary I-FABP levels in neonates with poor outcome (n = 5) were significantly higher as compared with I-FABP levels in neonates with good outcome (n = 16) (P < 0.01). A clinically significant cutoff value of 963 pg/ml was found to discriminate between infants with poor outcome and those with good outcome (sensitivity 80%, specificity 94%). CONCLUSION: Noninvasive urinary I-FABP measurement at time of refeeding differentiates neonates with poor outcome from neonates with good outcome in NEC. Urinary I-FABP measurement may therefore be helpful in the timing of EF in neonates with NEC.


Assuntos
Nutrição Enteral , Enterocolite Necrosante/terapia , Células Epiteliais/metabolismo , Mucosa Intestinal/metabolismo , Biomarcadores/urina , Nutrição Enteral/efeitos adversos , Nutrição Enteral/mortalidade , Enterocolite Necrosante/mortalidade , Enterocolite Necrosante/patologia , Enterocolite Necrosante/urina , Células Epiteliais/patologia , Proteínas de Ligação a Ácido Graxo/urina , Feminino , Humanos , Lactente , Recém-Nascido , Mucosa Intestinal/patologia , Masculino , Nutrição Parenteral Total , Valor Preditivo dos Testes , Fatores de Tempo , Resultado do Tratamento , Urinálise
18.
J Pediatr Surg ; 47(9): 1640-5, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22974599

RESUMO

BACKGROUND: Diagnosis of necrotizing enterocolitis (NEC), prevalent in premature infants, remains challenging. Enterocyte damage in NEC can be assessed by intestinal fatty acid-binding protein (I-FABP), with a sensitivity of 93% and a specificity of 90%. Numerous markers of inflammation are known, such as serum amyloid A (SAA) and fecal calprotectin. PURPOSE: The aim of the present study was to evaluate which combination of noninvasive measurement of inflammatory markers and I-FABP improves the diagnostic accuracy in neonates suspected for NEC. METHODS: In 62 neonates with clinical suspicion of NEC (29 with final diagnosis of NEC), urinary I-FABP, urinary SAA, and fecal calprotectin levels were determined quantitatively. Diagnostic accuracy was calculated for the combinations I-FABP-SAA and I-FABP-fecal calprotectin, using a multivariable logistic regression model. RESULTS: The combination of SAA and I-FABP did not increase the diagnostic accuracy of I-FABP. However, the combination of fecal calprotectin and I-FABP improved accuracy significantly. The combination of urinary I-FABP and fecal calprotectin measurement produced a sensitivity of 94%, a specificity of 79%, a positive likelihood ratio of 4.48, and a negative likelihood ratio of 0.08. CONCLUSION: The combination of noninvasive measurement of I-FABP and fecal calprotectin seems promising for diagnosing NEC at an early time point. Prospective analysis is required to confirm this finding and to evaluate better treatment strategies based on noninvasive measurement of I-FABP and calprotectin.


Assuntos
Enterocolite Necrosante/diagnóstico , Proteínas de Ligação a Ácido Graxo/urina , Doenças do Prematuro/diagnóstico , Complexo Antígeno L1 Leucocitário/metabolismo , Proteína Amiloide A Sérica/urina , Biomarcadores/metabolismo , Enterocolite Necrosante/metabolismo , Ensaio de Imunoadsorção Enzimática , Fezes/química , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Doenças do Prematuro/metabolismo , Funções Verossimilhança , Modelos Logísticos , Masculino , Análise Multivariada , Curva ROC , Sensibilidade e Especificidade
19.
Anal Chim Acta ; 713: 1-6, 2012 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-22200301

RESUMO

An enzymatic fluorimetric method for the determination of polyphenol compounds in beverages is described, which is based on the temporal inhibition caused by these compounds on the oxidation of the long wavelength fluorophor indocyanine green (λ(ex) 764 nm, λ(em) 806 nm), in the presence of the enzyme laccase and positively charged gold nanoparticles (AuNPs). The oxidation of the dye gives rise to a fast decrease in its fluorescence, but it is delayed by the polyphenol, obtaining a time period directly proportional to its concentration, which has been used as the analytical parameter. The behaviour of several benzenediols and benzenetriols in the system and the modification of the activity of the enzyme by its interaction with AuNPs have been studied. The system has been optimized using gallic acid as a polyphenol model, but the dynamic ranges of the calibration graphs and the detection limits for several of the polyphenols assayed were obtained (µmol L(-1)): gallic acid (0.13-5, 0.04), catechol (0.08-5, 0.01), hydroquinone (0.05-2, 0.01), hydroxyhydroquinone (0.09-5, 0.03), pyrogallol (0.17-5, 0.04). Most of the values of the regression coefficients were 0.999 and the precision of the method, expressed as RSD% and checked at two concentration levels of each analyte, ranged between 1.8 and 5.6%. The method has been applied to the determination of polyphenol content in several foodstuff samples and the results compared with those obtained with the standard Folin-Ciocalteu method.


Assuntos
Bebidas/análise , Fluorometria , Ouro/química , Lacase/metabolismo , Nanopartículas Metálicas/química , Polifenóis/análise , Ácido Gálico/análise , Verde de Indocianina/química , Lacase/química , Oxirredução
20.
Talanta ; 85(5): 2391-6, 2011 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-21962658

RESUMO

A simple and fast immunoaffinity method is proposed for the determination of gliadins for the first time using gold nanoparticles (AuNPs) as labels. The tracer used consists in a gliadin-AuNP conjugate prepared by the adsorption of gliadins onto the nanoparticle surface. Two AuNP sizes with diameters of 10nm and 20 nm were assayed to compare the behaviour of the corresponding tracer in the assay. The method relies on the injection in a commercial Protein G column of a preincubated mixture containing gliadins, polyclonal anti-gliadin antibodies, and the gliadin-AuNP tracer. This approach allows the separation of free and bound tracer fractions without any additional elution step, and the direct measurement of the resonance light scattering intensity of the free tracer through the peak height of the immunochromatogram, which is proportional to the analyte concentration. The immunocolumn can be used up to 25 times without eluting and it can be regenerated for at least 20 times. The dynamic ranges of the calibration graphs and the detection limits are 0.5-15.0 and 1.5-15.0 µg mL(-1) gliadins, and 0.2 µg mL(-1) and 0.8 µg mL(-1) gliadins, using 20-nm and 10-nm Au-NPs as labels, respectively. The precision, expressed as relative standard deviation, ranges between 2.7% and 2.9% using 20-nm AuNPs and 4% and 6.1% for 10-nm AuNPs. The method has been applied to the determination of the prolamin fraction in beer samples, obtaining recovery values in the range 71.2% and 101.7%.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...